CRC: Centre de Recherche du Cyclotron
|
HIF: Heavy Ion irradiation facility
Installation build to measure the response of electronic components to single event effects.
Two heavy ions “cocktails” covering a wide range of LET and ranges, allowing to fully characterize SEE response of electronic components.
Cocktail No 1: High LET
M/Q |
Ion |
DUT energy [MeV] |
Range [µm Si] |
LET [MeV/mg/cm²] |
---|---|---|---|---|
5 |
40 Ar 8+ |
151 |
40 |
15.9 |
5 |
20 Ne 4+ |
78 |
45 |
6.4 |
5 |
15 N 3+ |
60 |
59 |
3.3 |
4.96 |
124 Xe 25+ |
420 |
37 |
67.7 |
4.94 |
84 Kr 17+ |
305 |
39 |
40.4 |
Cocktail No 2: High penetration
M/Q |
Ion |
DUT energy [MeV] |
Range [µm Si] |
LET [MeV/mg/cm²] |
---|---|---|---|---|
3.25 |
13 C 4+ |
131 |
292 |
1.1 |
3.14 |
22 Ne 7+ |
235 |
216 |
3 |
3.33 |
40 Ar 12+ |
372 |
117 |
10.2 |
3.22 |
58 Ni 18+ |
567 |
100 |
20.4 |
3.32 |
83 Kr 25+ |
756 |
92 |
32.6 |
3.54 |
124 Xe 35+ |
995 |
73.1 |
62.5 |
|
Both cocktails have close M/Q (~5 for the high LET and ~ 3.3 for the high penetration), allowing a fast ion changing within the same cocktail just modifying slightly the magnetic field and/or the RF. The beam flux is variable between a few particles/s.cm² and 1·104particles/s.cm². The beam flux can be modified from the user station; this is done with injection grids (for a constant attenuation factor) or by inflector bias variations (for intermediates values). The Homogeneity is ± 10 % on a 25 mm diameter.All irradiations are done in vacuum and for most of the ions naked chips are needed.
Please contact the beam line responsible person to obtain a detailed description of the mechanical constraints and the available feed-through.
Reimbursement Information
The claim form must be filled in and returned.
Travel costs for two people and hotel costs for one or two nights may be covered by AIDA-2020 for each project approved as well as the cost of shipping samples.
Contact